Plate Nº 48 · recorded November 17, 2026

Chemistry & MaterialsReported finding

Breath sensor detects liver-linked compound at 10 parts per billion

A 2026 ACS Nano study reports that a filtered breath sensor detected dimethyl sulfide at 10 ppb despite hydrogen sulfide and 90% humidity, improving a proposed noninvasive liver disease biomarker.

By Nathan Brooks3 min read660 words

New gas sensor detects liver disease–related compounds in breath
Plate Nº 48New gas sensor detects liver disease–related compounds in breath — Kost9n4 / pixabay

By Nathan Brooks

A new breath gas sensor detected dimethyl sulfide at 10 parts per billion (ppb) under 90% relative humidity, according to a 2026 ACS Nano study. With a new filter, the device raised its response ratio for dimethyl sulfide over hydrogen sulfide from 3.3 to 50.4.

Parts per billion, or ppb, measures gas concentration as one billionth of the sample. Dimethyl sulfide normally occurs in human breath at low concentrations. Levels above 30 ppb have been associated with cirrhosis, a chronic liver condition, and hypermethioninemia, a condition involving excess methionine, an amino acid.

Those links make dimethyl sulfide a candidate biomarker, meaning a measurable substance that can signal a biological condition. Ruofan Zhang and colleagues said the results highlight the sensor’s “potential for noninvasive liver disease screening through breath analysis.” Noninvasive screening uses breath rather than a tissue sample.

The finding supports further development, but the study does not show that a breath reading can diagnose liver disease on its own.

What problem did the sensor need to solve?

Breath already contains hydrogen sulfide, another gas that can interfere with dimethyl sulfide detection. High humidity, which measures how much water vapor the air holds, creates a second obstacle. Together, those conditions make tiny dimethyl sulfide signals harder to measure accurately.

The researchers came from the Hefei Institutes of Physical Science of the Chinese Academy of Sciences. They worked with the Key Laboratory of Odor Pollution Control of the Ministry of Ecology and Environment and Shenzhen Technology University. The three-way collaboration developed the sensor for use in chemically complex breath.

How does the filter improve detection?

The team added a thin layer made from copper oxide and aluminum oxide, two metal-oxide materials. The layer traps hydrogen sulfide before it reaches the sensor’s palladium-containing tungsten-oxide sensing material, while dimethyl sulfide can pass through. It also reduces interference from moisture.

That arrangement gives the sensor a clearer signal from its target gas. The response ratio compares the device’s reaction to dimethyl sulfide with its reaction to hydrogen sulfide; a higher ratio means better separation. Moving from 3.3 to 50.4 made the response roughly 15 times stronger relative to the interfering gas.

Humidity did not defeat the device. Under 90% relative humidity, meaning air nearly saturated with water vapor, the sensor still detected dimethyl sulfide at 10 ppb. The study did not establish a clinical cutoff for deciding whether a person has liver disease.

Did the sensor work in patient-like breath?

The researchers tested breath samples designed to simulate those of people with liver disease. In those complex mixtures, the sensor detected small changes in dimethyl sulfide concentrations. The result shows that the filter can preserve target-gas detection when other breath compounds and moisture are present.

The test remains a laboratory demonstration. The reported samples were designed to resemble patient breath; the study does not describe a clinical trial using samples from recruited patients. It also does not report how often the sensor would correctly identify liver disease or falsely flag people without it.

What has the study established?

The 2026 paper establishes a materials advance: the added filter greatly improves dimethyl sulfide selectivity, meaning the ability to favor the target gas over an interfering one, despite hydrogen sulfide and high humidity. The researchers propose breath-based liver disease screening using noninvasive analysis of dimethyl sulfide as a biomarker.

Clinical use would require testing in actual patients and comparison with established screening approaches. It would also require repeatable results across people, devices, and routine breath-testing conditions. Those data are not part of this report, so the sensor remains a promising research tool rather than a validated diagnostic test.

What are the publication details?

  • Lead author: Ruofan Zhang and colleagues
  • Journal: ACS Nano, 2026
  • Title: “Exclusive Detection of Dimethyl Sulfide by a Pd–WO3 Sensor with the CuO/Al2O3 Filtering Overlayer”
  • DOI: 10.1021/acsnano.6c07624
  • Key concept: Biomarkers

via phys.org/rss-feed/ (Source)

Filed under

  • dimethyl-sulfide
  • breath-sensor
  • gas-sensors
  • biomarkers
  • liver-disease
Share this article:

More from Nathan Brooks

Nathan Brooks

Show full bio

Market editor covering companies, deals and strategy in general science news at SciBeat.

456 articles