Recorded November 22, 2026
Health & Medicine ResearchReported finding
X-ray Software Tracks Thousands of Fibres Inside Spinal Discs Under Pressure
STFC's iDVC software, paired with a new TomoSAXS X-ray technique, tracks how thousands of individual collagen fibres in spinal discs deform under pressure. Published in Nature.
By James Calloway4 min read712 words
In brief
- Research published in Nature, led by Queen Mary University of London and University College London
- iDVC software tracks thousands of distinct points in 3D inside compressed spinal discs
- TomoSAXS combines phase-contrast CT and small-angle X-ray scattering to image fibres and fibrils
- iDVC was funded by the Collaborative Computational Project in Tomographic Imaging, plus ALC and CoSeC support

Software developed by the UK's Science and Technology Facilities Council (STFC) has tracked how thousands of individual collagen fibres inside human spinal discs move and deform under pressure — a measurement scientists could not make before. The research, led by Queen Mary University of London and University College London, is published in the journal Nature.
The findings could help explain why spinal discs deteriorate as we age, and why some regions of the disc are more vulnerable to damage than others. Note the hedge: could. The study demonstrates a measurement method; clinical payoffs remain downstream.
Why discs matter
Spinal discs are the spine's shock absorbers. They let the spine move and share the load from everyday actions — standing, walking, carrying weight. Until now, researchers struggled to see how the collagen structures inside a disc work together when it gets compressed. They could measure averages across the whole disc. They could not follow what individual fibres actually do.
That gap is what the new work closes.
What did the researchers actually build?
Two pieces came together. The first is a new imaging technique called TomoSAXS, which combines two types of X-ray imaging:
- Phase-contrast CT, which shows the larger collagen fibres and how they move
- Small-angle X-ray scattering, which reveals the smaller collagen 'fibrils' sitting inside those fibres
The second piece is the analysis software: interactive Digital Volume Correlation, or iDVC, developed by STFC Scientific Computing. The tool compares 3D X-ray images of a disc taken before and after compression. From those image pairs, it calculates exactly where parts of the tissue moved and how they changed shape.
Crucially, iDVC can follow individual fibres rather than reporting one average change across the whole disc. That is the step change here. Averages hide the mechanics; individual fibre tracks expose them.
Dr Danica Sugic, a computational scientist in the Computed Tomography and Imaging group at STFC Scientific Computing, said: "Tissue and fibre deformations under compression are extremely intricate and difficult to track manually. The iDVC software uniquely provides very precise measurements and 3D rendering of how thousands of distinct points move within the disc."
Thousands of distinct points, tracked in three dimensions. That is the headline number of this method.
What does this change for spine research?
For researchers, it opens a way to test, mechanically, why discs break down with age and why certain areas fail first. If deterioration starts with specific fibre behaviours under load, this tool can now see those behaviours directly rather than infer them. For patients, nothing changes yet — no therapy, no diagnostic test emerges from this paper. The work is foundational, and the researchers themselves frame its impact as explanatory.
The usual caveats apply. This is a methodological study published in a single Nature paper; the release does not report sample sizes, whether the discs were human or animal, or how the technique performs across age groups. Those details will determine how fast the findings translate into anything clinical.
The quiet story: long-term software funding
There is a second story tucked inside this one. The iDVC code was not written for this project. STFC Scientific Computing developed it with funding from the Collaborative Computational Project in Tomographic Imaging, with further support from the Ada Lovelace Centre (ALC) and the Computational Science Centre for Research Communities (CoSeC).
The team also worked with Professor Brian Bay of Oregon State University, who pioneered digital volume correlation — the underlying technique — years before this application.
Dr Edoardo Pasca, Head of the Computed Tomography and Imaging group at STFC Scientific Computing, said: "This work demonstrates the importance of long-term funding for software development, such as this enabled by CoSeC and ALC. Our computational capability in this project was a key element in revealing how the spine's shock-absorbing discs behave."
Pasca added a longer view: "In the long term it will help to achieve the goal of improving lives, which is one of the UK's research and innovation priorities."
In the long term — again, the hedge is honest. Software built without a specific disease target in mind became the instrument that made this Nature paper possible. That argument for patient, multi-year funding of scientific computing is, by the researchers' own telling, part of the result.
via UKRI News (Source)
More from James Calloway
Show full bio
Staff writer covering regulation, policy and their impact on general science news at SciBeat.
570 articles
Nearby plates
- 3D human muscle model reproduces signs of aging in tissue
- Large CT Study Finds Bigger Abdominal Muscles No Shield Against Back Pain
- Spine Bone Density on Chest CT Scans Linked to Memory Decline
- Scientists Find the Stem Cell That Builds Tendons and Ligaments
- Cell Skeleton Stiffens Like Compressed Wool, Physicists Find