Recorded November 22, 2026
Chemistry & MaterialsReported finding
X-ray Technique Measures Temperature at 5 Million Atmospheres
LLNL physicists squeezed tantalum past 500 gigapascals at NIF and measured its temperature with L-edge EXAFS for the first time — revealing heating their models had missed.
By Nathan Brooks3 min read694 words
In brief
- Tantalum held its crystal structure above 500 gigapascals, about 5 million times atmospheric pressure.
- The study marks the first use of L-edge EXAFS temperature measurement at the National Ignition Facility.
- At ~400 gigapascals the sample ran much hotter than models predicted, possibly due to plasma X-rays from the beryllium target.
- Published in Physical Review B, 2026; DOI: 10.1103/klbh-bmbl.
- Collaborators include LLNL, Los Alamos, Sandia, Nevada National Security Site, Washington State University and Rochester's LLE.

Scientists at Lawrence Livermore National Laboratory have measured the temperature of a metal squeezed to roughly 5 million times Earth's atmospheric pressure — and found their computer models were missing part of the picture. The study, published in Physical Review B in 2026, compressed tantalum past 500 gigapascals at the National Ignition Facility (NIF) and captured its temperature with an X-ray technique never before used there.
"Measuring temperature under these extreme conditions is extraordinarily challenging, but it's essential to understanding how materials respond," said LLNL physicist Andrew Krygier, who led the research. "These experiments give us a new way to test our models, identify sources of heating we might otherwise miss and improve our ability to predict material behavior."
How do you take a sample's temperature in billionths of a second?
That timing is the core problem. Extreme compression at NIF lasts only billionths of a second, and the few existing measurement techniques each carry their own limitations and uncertainties. Temperature matters because it shapes nearly everything about how a material responds — its compressibility, strength, phase stability and transport properties.
The team used a technique called extended X-ray absorption fine structure, or EXAFS. In plain terms, it tracks subtle changes in how a material absorbs X-rays, which reveals both the distances between neighboring atoms and how much those atoms are vibrating. That vibration is the fingerprint of temperature. Researchers then compare the measured signal against physics-based computer calculations to pin down how hot the sample actually got.
Because EXAFS captures everything in a single experiment, it fits NIF's brief, high-pressure conditions well. The team measured absorption at tantalum's L-edge — an energy region of its X-ray spectrum — which marks the first use of L-edge EXAFS at the facility and opens a practical path to studying heavy elements that resist conventional methods.
"L-edge EXAFS is more challenging due to smaller signals," said LLNL physicist Yuan Ping, the campaign's principal investigator. "The energetic NIF laser and high-resolution diagnostic development in past years enabled these high-quality measurements."
What did the tantalum reveal?
Two findings stand out. First, X-ray diffraction showed tantalum kept the same basic crystal structure at pressures above 500 gigapascals, with no sign of an alternative structure that earlier calculations had predicted might appear.
Second, the temperature readings exposed heating the models hadn't accounted for. At roughly 200 gigapascals, EXAFS temperatures matched the computer simulations only when the models included tantalum's strength. Tantalum resists compression, so some of the compression energy converts into extra heat.
At roughly 400 gigapascals, the gap widened: the sample ran much hotter than predicted. The researchers found that X-rays emitted by plasma could plausibly explain much of the difference. That plasma formed when NIF lasers struck the target's outer beryllium layer, and trace amounts of iron and nickel in the beryllium may have boosted the X-ray emission. The team cautions the extent of that effect remains uncertain.
"This result has already changed how we model the laser-plasma interaction and how we think about designing future high-pressure experiments," Krygier said.
Why does one metal's temperature matter?
The work builds on earlier NIF experiments that used EXAFS to measure temperatures in copper. Both campaigns turned up unexpected heating, which underscores why directly measuring temperature beats relying on simulations alone. If a sample runs hotter than models expect, researchers could misread its strength, melting behavior or structural changes.
The stakes extend to nuclear security. EXAFS measurements give the National Nuclear Security Administration (NNSA) experimental data to test the models underpinning stockpile stewardship and modernization efforts.
The collaboration spans LLNL, Los Alamos and Sandia national laboratories, the Nevada National Security Site, Washington State University and the University of Rochester's Laboratory for Laser Energetics. The EXAFS bulk-temperature measurements complement surface-radiance-based methods on other platforms, part of a wider push to validate temperature measurement techniques across the nuclear security enterprise.
The paper is A. Krygier et al., "Crystal structure and temperature of tantalum dynamically compressed to hundreds of gigapascals," Physical Review B (2026), DOI: 10.1103/klbh-bmbl.
via phys.org/rss-feed/ (Source)
More from Nathan Brooks
Show full bio
Market editor covering companies, deals and strategy in general science news at SciBeat.
563 articles
Nearby plates
- X-ray laser hits 0.04 nanometers, breaking its own wavelength record
- Nanoindentation recrystallizes molybdenum at room temperature
- Superconductor's Giant Domains Challenge a 40-Year Model
- Two Alloys Refuse to Crack at −424°F — Here's What That Does and Doesn't Mean
- Tiangong team sets cold record with a seven-second atom cloud